I thought the test was very effective. They found a faster, more accurate and, more comfortable method for weighing and determining wrestler's lowest wrestling weight. The tests they ran on the college wrestlers were done right and were very effective. The NCAA should start using it some time soon. A more accurate method ensures the safety of the wrestlers. Dropping below a certain percent body fat is not safe, and can have negative effects on the body. Keeping people safe and making their lives easier; thats just a good test.
Showing posts with label body weight. Show all posts
Showing posts with label body weight. Show all posts
Sunday, March 30, 2008
Sunday, March 23, 2008
New Method for Weight Management
Unhealthy weight loss leads to unsafe participation in matches. A minimum wrestling weight is determined at the beginning of the wrestling season by body weight, body composition, and specific gravity of urine. The weight is determined by finding the wrestler’s mass without any fat plus five percent for fat. Five percent body fat is the lowest healthy percent, so when cutting weight for a match, the wrestler will not be able to go below five percent and still wrestle. Currently, the NCAA uses hydrostatic weighing together with skin folds for determining the lowest wrestling weight. These methods are not always very accurate. New methods have been developed such as air displacement plethysmography. Air displacement plethysmography is a densitometric method that relies on measurement of mass and volume to calculate body density. Densitometry is the measurement of density by measuring the time a projected wave takes to go out and return to a sensor. Advantages of air displacement plethysmography are it requires less technical expertise, it is more efficient and comfortable than hydrostatic weighing. Testing showed that air displacement plethysmography had very similar results to hydrostatic weighing, but some major variations cause questions. The study evaluated the accuracy of air displacement plethysmography for measuring body density compared to the current method. The study included 66 division 1 collegiate wrestlers, some from each weight class. In a hydrated and dehydrated state, air displacement plethysmography and current tests were similar.
Utter, Alan C., Fredric L. Goss, and Pamela D. Swan. "Evaluation of Air Displacement for Assessing Body Composition of Collegiate Wrestlers." Medicine and Science in Sports and Exercise 35.3 (2003): 500-5.
Subscribe to:
Posts (Atom)